Figure 2. Cold Start Device Removal.
Figure 5. Cold Start Device Installation.

Technical Manual For Crane, Wheel Mounted, Hydraulic, Light, 7 1/2 Ton Page Navigation
  315    316    317    318    319  320  321    322    323    324    325  
img
. . .
TM 5-3810-305-23
0051
REMOVAL - Continued
10.
Remove knob (Figure 4, Item 1), locknut (Figure 4, Item 3), washer (Figure 4, Item 4), and cable
(Figure 4, Item 2) from vehicle. Discard locknut.
1
3
4
2
M0251105
Figure 4.
Cold Start Device Removal.
END OF TASK
CLEANING
Clean parts IAW General Maintenance Instructions (WP 0162).
END OF TASK
INSPECTION
Inspect parts IAW General Maintenance Instructions (WP 0162).
END OF TASK