TM 5-3810-305-23
0080
REMOVAL
NOTE
Tag all wire assemblies before disconnecting to aid in installation. Remove tags
following maintenance.
1.
Disconnect electrical connections (Figure 1, Item 1).
2.
Remove two nuts (Figure 1, Item 2), two washers (Figure 1, Item 3), lockwashers (Figure 1, Item 4), and backup
alarm (Figure 1, Item 6) from mounting studs (Figure 1, Item 5). Discard lockwashers.
1
2,3,4
5
6
M0125105
Figure 1. Back Up Alarm Removal.
END OF TASK
CLEANING
Clean parts IAW General Maintenance Instructions (WP 0162).
END OF TASK
INSPECTION
Inspect parts IAW General Maintenance Instructions (WP 0162).
END OF TASK
03/15/2011Rel(1.8)root(maintwp)wpno(M00086)