MSD-ICE DCA CONNECTOR/RESISTOR MODULE MAINTENANCE
Figure 2. MSD-ICE DCA Connector Resistor/Module Installation.

Technical Manual For Crane, Wheel Mounted, Hydraulic, Light, 7 1/2 Ton Page Navigation
  516    517    518    519    520  521  522    523    524    525    526  
img
. . .
TM 5-3810-305-23
0083
REMOVAL
NOTE
Tag and identify all wires and wiring harnesses to aid in installation.
1.
Remove MSD-ICE cap (Figure 1, Item 3), four nuts (Figure 1, Item 6), ground wires (Figure 1, Item 5), screws
(Figure 1, Item 4), and MSD-ICE diagnostic connector (Figure 1, Item 7) from inside rear cab wall.
2.
Remove resistor cap (Figure 1, Item 1), four nuts (Figure 1, Item 8), screws (Figure 1, Item 2), and resistor
module (Figure 1, Item 9) from inside rear cab wall.
3.
Remove nut (Figure 1, Item 11), washer (Figure 1, Item 12), and fuel toggle switch (Figure 1, Item 10) from
inside rear cab wall.
1
8
7
9
2
3
6
4
5
10
11,12
M0155105
Figure 1.
MSD-ICE DCA Connector Resistor/Module Removal.
END OF TASK
CLEANING
Clean parts IAW General Maintenance Instructions (WP 0162).
END OF TASK
INSPECTION
Inspect parts IAW General Maintenance Instructions (WP 0162).
END OF TASK
0083-2
03/15/2011Rel(1.8)root(maintwp)wpno(M00089)