TM 5-3810-305-23
0156
REMOVAL
WARNING
Remove jewelry and disconnect battery negative ground cable before performing
maintenance on this equipment. Failure to follow this warning may result in injury or death
to personnel.
1.
Start engine. Take up cable on winch, maintaining tension on cable at all times.
2.
Place carrier upon outriggers. Shut engine OFF (TM 5-3810-305-10).
3.
Disconnect battery negative ground cable (WP 0076).
4.
Tag and disconnect electrical wiring (Figure 1, Item 1) from boom base, and insulate electrical connectors.
5.
1
M0616105
Figure 1. Boom Assembly Removal.
WARNING
Never disconnect hydraulic lines or fittings before venting pressure. Turn dipstick cap 1/4 turn
to safety notch to relieve pressure. Failure to follow this warning may cause death or injury
to personnel.
6.
Turn dipstick cap 1/4 turn to safety notch to relieve pressure.
03/15/2011Rel(1.8)root(maintwp)wpno(M00172)