TM 5-3810-305-23
0156
INSTALLATION - Continued
2
1
5
4
3
M0644105
Figure 30. Boom Assembly Installation.
5.
Start engine. Raise boom 10 degrees and remove suitable bracing material. Hold anti-two block BY-PASS
switch and lower boom. Shut engine OFF (TM 5-3810-305-10).
WARNING
Never disconnect hydraulic lines or fittings before venting pressure. Turn dipstick cap 1/4 turn
to safety notch to relieve pressure. Failure to follow this warning may cause death or injury
to personnel.
6.
Turn dipstick cap 1/4 turn to safety notch to relieve pressure.
03/15/2011Rel(1.8)root(maintwp)wpno(M00172)