TM 5-3810-306-20fInstall capacitor (10), diode silicon rectifier (9)and wires to terminal block (11). Secure bytightening screws.g.Install four wire pins in each relay plug (8)according to diagram shown. Install relays (7).h.Install two wires 212 and 213 to resistor (6).i.Install wires and electrical connectors to relayK5 (5).j.Install wires 112, 30 and 781 to circuit breakers(4).k.Install wires 5A, 5B and 5C to buss bar on circuitbreakers (3).l.Install electrical connectors on flasher (2).m.Connect five electrical connectors on distributionpanel wiring harness (1).2.INSTALL DISTRIBUTION PANEL. (REFER TOPAGE 8-30.)3.INSTALL FRONT SIDE ACCESS PANEL (REFERTO PAGE 8-21.)4.CONNECT GROUND CABLE AT SHUNT.(REFER TO PAGE 8-109.)5.CHECK FOR PROPER OPERATION OF ALLELECTRICAL COMPONENTS. (REFER TO TM 5-3810-306-10.)END OF TASK8-28