TM5-3810-305-10
NOTE
Two personnel are required on
the deck next to the upperstruc-
ture, one on each side, to observe
the upperstructure alignment.
Another person is required on the
ground to handle the tether rope.
2. Continue to hoist assembly high enough to
clear rotary manifold and electrical collector
ring cover (1 to 2 in. [25.4 to 50.8 mm] is
sufficient).
3. By pushing on lift arm and pulling with tether
rope, manually swing upperstructure into
mounting position with boom pointing in a 10
oclock direction on left side of carrier (Figure
5-38).
Keep hands and arms clear of all
pinch points while checking the
alignment of the upperstructure
and the carrier mounting surface.
Failure to follow this procedure
could cause SERIOUS INJURY.
CAUTION
Make sure the base plate opening
clears the connections on the
rotary manifold, Failure to
follow this procedure could cause
damage to equipment.
4. Slowly lower the upperstructure over rotary
manifold to within 0.5 in. (13 mm) of rotary
manifold.
Figure 5-38 Installing Upperstructure
5 - 3
4