T M 5 - 3 8 1 0 - 3 0 5 - 1
c.
d.
l Never disconnect hydraulic
lines or fittings before venting
pressure. Turn dipstick cap 1/4
turn to the safety notch to
relieve pressure. Failure to
follow this procedure could
cause SERIOUS INJURY.
l Turn the face during the
following procedure to avoid
having hydraulic oil splash in
face or eyes. Failure to follow
this procedure could cause
SERIOUS INJURY.
NOTE
During reconnection of hydraulic
quick disconnects, pressure
build-up may prevent reconnec-
tion. Striking the cone at the
center of the disconnect will
relieve the pressure.
Figure 5-14. Extension Hoses
Turn dipstick cap 1/4 turn to safety notch
to relieve pressure.
Locate two quick disconnect fittings that
extend down from two tees on winch valve
next to frame, underneath right side of
carrier. Remove protective dust caps and
connect male connectors of extension hose
H-10 to H-10 winch hose and extension
hose H-11 to H- 11 winch hose (Figure 5-
35). Attach female connectors of exten-
sion hose H-10 to H-10 valve fitting and
extension hose H-11 to H-11 valve fitting.
Stow plugs in tool box.
Winch hoses are now attached from valve to
Figure 5-35 Quick Disconnet Fittings
original winch hoses with these extensions.
5-29