Figure 2. Suction Hydraulics Installation.
ROTARY MANIFOLD QUICK DISCONNECTS (TYPE II) MAINTENANCE - Continued

Technical Manual For Crane, Wheel Mounted, Hydraulic, Light, 7 1/2 Ton Page Navigation
  961    962    963    964    965  966  967    968    969    970    971  
img
. . . . . . . . . . . . . . . .
TM 5-3810-305-23
0145
FIELD MAINTENANCE
ROTARY MANIFOLD QUICK DISCONNECTS (TYPE II) MAINTENANCE
INITIAL SETUP:
Materials/Parts (cont.)
Tools and Special Tools
Rag, Wiping (WP 0170, Table 1, Item 52) Qty: 1
Tool Kit, General Mechanic's (WP 0171, Table 1,
Item 17)
Tag, Marker (WP 0170, Table 1, Item 68) Qty:  1
Pan, Drain (WP 0171, Table 1, Item 39)
Washer, Lock (WP 0172, Table 1, Item 48)
Suitable Lifting Device 5,000-lb (2,268 kgs)
Qty: 3
Minimum Capacity
References
Materials/Parts
WP 0076
Cap Set, Protective, Dust and Moisture Seal
WP 0138
(WP 0170, Table 1, Item 7) Qty: 1
WP 0162
Lubricating Oil, Hydraulic MIL-L-2104 OE, 10
Grade (WP 0170, Table 1, Item 42) Qty: 1
Equipment Condition
O-Ring (WP 0172, Table 1, Item 28) Qty: 2
Vehicle parked on level ground (TM
O-Ring (WP 0172, Table 1, Item 43) Qty: 6
5-3810-305-10)
O-Ring (WP 0172, Table 1, Item 120) Qty: 6
Deck plates removed (WP 0122)
O-Ring (WP 0172, Table 1, Item 146) Qty:  6
REMOVAL
1.
Start engine and raise boom to a height suitable to provide access to the inside of upperstructure frame
(TM 5-3810-305-10).
WARNING
Weight of boom is approximately 3,100 lb (1,406 kg). Use adequate lifting equipment to lift
and support boom. DO NOT lift over personnel or let personnel walk underneath suspended
load. Failure to follow this warning may cause injury or death to personnel.
2.
Use lifting device to support boom.
3.
Shut engine OFF.
0145-1
03/15/2011Rel(1.8)root(maintwp)wpno(M00162)