UPPERSTRUCTURE MAINTENANCE
Figure 2. Upperstructure Removal.

Technical Manual For Crane, Wheel Mounted, Hydraulic, Light, 7 1/2 Ton Page Navigation
  1086    1087    1088    1089    1090  1091  1092    1093    1094    1095    1096  
img
.
TM 5-3810-305-23
0158
REMOVAL - Continued
Upperstructure - Continued
WARNING
Never disconnect hydraulic lines or fittings before venting pressure. Turn dipstick cap 1/4 turn
to safety notch to relieve pressure. Failure to follow this warning may cause death or injury
to personnel.
2.
Turn dipstick cap 1/4 turn to safety notch to relieve pressure.
3.
Tag and disconnect two boom extend cylinder hoses (Figure 1, Item 1) and boom hoist cylinder hoses from
rotary manifold (Figure 1, Item 2). Plug hoses and cap manifold port elbows.
1
2
M0611105
Figure 1.
Upperstructure Removal.
4.
Tag and disconnect two winch hydraulic tubes (Figure 2, Item 1) from rotary manifold (Figure 2, Item 8).
Plug tubes and cap manifold port elbows.
0158-2
03/15/2011Rel(1.8)root(maintwp)wpno(M00175)