Figure 1. Upperstructure Removal.
UPPERSTRUCTURE MAINTENANCE - Continued

Technical Manual For Crane, Wheel Mounted, Hydraulic, Light, 7 1/2 Ton Page Navigation
  1087    1088    1089    1090    1091  1092  1093    1094    1095    1096    1097  
img
.
TM 5-3810-305-23
0158
REMOVAL - Continued
Upperstructure - Continued
WARNING
Remove jewelry and disconnect battery negative ground cable before performing
maintenance on this equipment. Failure to follow this warning may result in injury or death
to personnel.
5.
Remove and discard tiedown straps and tag and disconnect collector ring wiring harness (Figure 2, Item 9)
from top of rotary manifold (Figure 2, Item 8).
6.
Remove stop pin (Figure 2, Item 6) and lockwasher (Figure 2, Item 7) from torque arm bracket
(Figure 2, Item 5). Discard lockwasher.
7.
Remove 10 capscrews (Figure 2, Item 3) and 20 washers (Figure 2, Item 4) from inside of upperstructure
(Figure 2, Item 2).
1
2
3
9
8
4
5
7
6
M0612105
Figure 2.
Upperstructure Removal.