TM 5-3810-306-20Section II. HOIST MAINTENANCEHOIST CABLE IDLER INSTALLATIONTOOLS: General mechanic’s tool kit: automotive (5180-00-177-7033)SUPPLIES:Lockwasher (Item 16, Appendix C)Lockwasher (Item 87, Appendix C)EQUIPMENT CONDITIONS:Disconnect ground cable at shunt. (Refer to page 8-109.)REMOVAL:1.REMOVE CABLE IDLER FROM HOIST.a.Remove bolt (1), lockwasher (2), and end cap(3) from idler drums shaft (4). Discardlockwasher (2).b.Remove shaft (4) from drum (5). Remove drum(5) and spacers (9).c.Remove four bolts (7) and lockwashers (8)securing cable idler frame (6) to hoist. Discardlockwashers (8).INSTALLATION:1.INSTALL CABLE IDLER.a.Install cable idler frame (6) and secure with newlockwashers (8) and bolts (7).b.Install shaft (4) through hole in cable idler frame.c.Install the drum (5) and spacers (9) on shaft (4).e.Install end cap (3), washer (2) and bolt (1) onend of shaft (4).2.CONNECT GROUND CABLE AT SHUNT. (REFERTO PAGE 8-109.)END OF TASK17-12