TM 5-3810-305-23
0163
ASSEMBLY - Continued
Female-Type Panel Mounting Receptacle with Ridged Locking Nut
1.
Strip cable insulation equal to depth of solder wells of socket contacts (Figure 16, Item 3).
2.
Slide nut (Figure 16, Item 5) over cable leads (Figure 16, Item 6).
3.
Slide grommet (Figure 16, Item 4) over cable leads (Figure 16, Item 6).
4.
Insert cable leads (Figure 16, Item 6) into solder wells of socket contacts (Figure 16, Item 3) and solder
(use rosin core solder only).
5.
Push insert (Figure 16, Item 2) into shell (Figure 16, Item 1) from rear until seated. Groove in insert must be
aligned with guide in shell to ensure proper fit.
6.
Push socket contacts (Figure 16, Item 3) into insert (Figure 16, Item 2) from rear until seated.
7.
Push grommet (Figure 16, Item 4) down cable leads (Figure 16, Item 6) and over solder wells of socket contacts
(Figure 16, Item 3).
8.
Screw nut (Figure 16, Item 5) onto shell assembly.
9.
Tape cable leads as required.
10.
6
5
4
3
2
1
M0146105
Figure 16. Electrical Harness Assembly.
03/15/2011Rel(1.8)root(maintwp)wpno(M00186)