TM 5-3810-305-23
0163
DISASSEMBLY - Continued
Male-Type Panel Mounting Receptacle
WARNING
Remove jewelry and disconnect battery negative ground cable before performing
maintenance on this equipment. Failure to follow this warning may result in injury or death
to personnel.
1.
Push pin contacts (Figure 4, Item 2) out through rear of insert (Figure 4, Item 3) with pin extractor.
2.
Unsolder cable leads (Figure 4, Item 1) from solder wells on pin contacts (Figure 4, Item 2).
3.
Slide insert (Figure 4, Item 3) out through rear of shell (Figure 4, Item 4).
4
3
2
1
M0135105
Figure 4. Electrical Harness Disassembly.