TM 5-3810-305-23
0163
DISASSEMBLY - Continued
Male-Type Panel Mounting Receptacle with Ridged Locking Nut
WARNING
Remove jewelry and disconnect battery negative ground cable before performing
maintenance on this equipment. Failure to follow this warning may result in injury or death
to personnel.
1.
Unscrew nut (Figure 6, Item 2) from shell assembly and slide back on cable.
2.
Push grommet (Figure 6, Item 3) back on cable leads (Figure 6, Item 1).
3.
Push pin contacts (Figure 6, Item 4) out through rear of insert (Figure 6, Item 5) with pin extractor.
4.
Push insert (Figure 6, Item 5) out through rear of shell (Figure 6, Item 6).
5.
Unsolder leads (Figure 6, Item 1) from pin contacts (Figure 6, Item 4).
6
5
4
3
2
1
M0137105
Figure 6. Electrical Harness Disassembly.
03/15/2011Rel(1.8)root(maintwp)wpno(M00186)