TM 5-3810-305-23
0163
DISASSEMBLY - Continued
Female-Type Panel Mounting Receptacle with Ridged Locking Nut
WARNING
Remove jewelry and disconnect battery negative ground cable before performing
maintenance on this equipment. Failure to follow this warning may result in injury or death
to personnel.
1.
Unscrew nut (Figure 5, Item 5) from shell assembly and slide back on cable.
2.
Slide grommet (Figure 5, Item 4) back on cable leads (Figure 5, Item 6).
3.
Push socket contacts (Figure 5, Item 3) out through front of insert (Figure 5, Item 2) with pin extractor.
4.
Push insert (Figure 5, Item 2) out through rear of shell (Figure 5, Item 1).
5.
Unsolder cable leads (Figure 5, Item 6) from socket contacts (Figure 5, Item 3).
6
5
4
3
2
1
M0136105
Figure 5. Electrical Harness Disassembly.
03/15/2011Rel(1.8)root(maintwp)wpno(M00186)