TM 5-3810-305-23
0163
DISASSEMBLY - Continued
Male-Type Plug with Ridged Locking Nut
WARNING
Remove jewelry and disconnect battery negative ground cable before performing
maintenance on this equipment. Failure to follow this warning may result in injury or death
to personnel.
1.
Unscrew nut (Figure 8, Item 2) from shell cables, assembly and slide back on cable.
2.
Push grommet (Figure 8, Item 3) back on cable leads (Figure 8, Item 1).
3.
Push coupling nut (Figure 8, Item 4) off shell assembly.
4.
Drive pin contacts (Figure 8, Item 5) out through rear of insert (Figure 8, Item 6) with pin extractor.
5.
Push insert (Figure 8, Item 6) out through rear of shell (Figure 8, Item 7).
6.
Unsolder cable leads (Figure 8, Item 1) from pin contacts (Figure 8, Item 5).
6
7
5
4
2
3
1
M0139105
Figure 8. Electrical Harness Disassembly.
03/15/2011Rel(1.8)root(maintwp)wpno(M00186)