TM 5-3810-305-23
0163
DISASSEMBLY - Continued
Cable Connectors
WARNING
Remove jewelry and disconnect battery negative ground cable before performing
maintenance on this equipment. Failure to follow this warning may result in injury or death
to personnel.
Cut and discard connectors for terminal-type cables, female cables with washers or sleeves, and male cables
with washers.
END OF TASK
ASSEMBLY
Terminal-Type Cable Connector
1.
Strip cable insulation equal to depth of well.
2.
Slide insulator (Figure 9, Item 2) over cable (Figure 9, Item 1).
3.
Insert cable (Figure 9, Item 1) into terminal (Figure 9, Item 3) well and crimp.
4.
Slide insulator (Figure 9, Item 2) over crimped end of terminal (Figure 9, Item 3).
5.
3
2
1
M0140105
Figure 9.
Electrical Harness Assembly.
03/15/2011Rel(1.8)root(maintwp)wpno(M00186)