TM 5-3810-306-20GAUGE REPLACEMENTTOOLS: General mechanic’s tool kit: automotive (5180-00-177-7033)SUPPLIES:NoneEQUIPMENT CONDITION:Disconnect ground cable at shunt. (Refer to page 8-109.)Left front control panel removed. (Refer to page 8-11.)REMOVAL:NOTEUse this task to remove and installcontrol panel gauges. Watertemperature gauge (1) with 24 V adapter(2) is shown.NOTE24 V adapter is not used on voltmeter.1.DISCONNECT ELECTRICAL WIRES (3) ANDREMOVE 24 V ADAPTER (2).2.DISCONNECT BULB (7) FROM SOCKET (8).a.Pull socket (8) from gauge (1).b.Remove filter cap (9) and discard if damaged.c.Inspect bulb (7) for damage. If damaged,replace bulb (7).3.REMOVE GAUGE (1).a.Remove two nuts (10) and lockwashers (11)securing mounting clamp 12)a.Tag electrical wires.b.Disconnect electrical wires.c.Remove two nuts (4), lockwashers (5) andelectrical tabs (6) holding 24 V adapter (2).8-17d.Lift 24 V adapter (2) from gauge (1).8-17