TM 5-3810-306-20
GAUGE REPLACEMENT
TOOLS: General mechanics tool kit: automotive (5180-00-177-7033)
SUPPLIES:
None
EQUIPMENT CONDITION:
Disconnect ground cable at shunt. (Refer to page 8-109.)
Left front control panel removed. (Refer to page 8-11.)
REMOVAL:
NOTE
Use this task to remove and install
control
panel
gauges.
Water
temperature gauge (1) with 24 V adapter
(2) is shown.
NOTE
24 V adapter is not used on voltmeter.
1.
DISCONNECT ELECTRICAL WIRES (3) AND
REMOVE 24 V ADAPTER (2).
2.
DISCONNECT BULB (7) FROM SOCKET (8).
a.
Pull socket (8) from gauge (1).
b.
Remove filter cap (9) and discard if damaged.
c.
Inspect bulb (7) for damage. If damaged,
replace bulb (7).
3.
REMOVE GAUGE (1).
a.
Remove two nuts (10) and lockwashers (11)
securing mounting clamp 12)
a.
Tag electrical wires.
b.
Disconnect electrical wires.
c.
Remove two nuts (4), lockwashers (5) and
electrical tabs (6) holding 24 V adapter (2).
8-17
d.
Lift 24 V adapter (2) from gauge (1).
8-17