TM 5-3810-306-20bHold gauge (1) in place. Lift off mounting clamp(12).. Push gauge (1) through panel.4.INSPECT PARTS FOR DAMAGE. REPLACEPARTS AS REQUIRED.INSTALLATION:1INSTALL GAUGE (1) AND CONNECT SOCKET (8)a.Put gauge (1) through panel.b.Install mounting clamp (12) and secure with twolockwashers (11) and nuts (10).c.Put bulb (7) in socket (8). Slide filter cap (9)over bulb (7)..d.Install socket (8) in back of gauge (1).2.INSTALL 24 V ADAPTER (2) AND CONNECTELECTRICAL WIRES (3).a.Install 24 V adapter (2), electrical tabs (6),lockwashers (5) and nuts (4). Tighten nuts (4).b.Remove tags and connect electrical wires.3.NSTALL LEFT FRONT CONTROL PANEL.(REFER TO PAGE 8-11.)4.CONNECT GROUND CABLE AT SHUNT. (REFERTO PAGE 8-109.)5.START ENGINE. MAKE SURE GAUGE (1)SHOWS PROPER READINGS. (REFER TO TM 5-3810-306-10)END OF TASK8-18
Integrated Publishing, Inc. - A (SDVOSB) Service Disabled Veteran Owned Small Business