TM 5-3810-306-20
b
Hold gauge (1) in place. Lift off mounting clamp
(12).
. Push gauge (1) through panel.
4.
INSPECT PARTS FOR DAMAGE. REPLACE
PARTS AS REQUIRED.
INSTALLATION:
1
INSTALL GAUGE (1) AND CONNECT SOCKET (8)
a.
Put gauge (1) through panel.
b.
Install mounting clamp (12) and secure with two
lockwashers (11) and nuts (10).
c.
Put bulb (7) in socket (8). Slide filter cap (9)
over bulb (7)..
d.
Install socket (8) in back of gauge (1).
2.
INSTALL 24 V ADAPTER (2) AND CONNECT
ELECTRICAL WIRES (3).
a.
Install 24 V adapter (2), electrical tabs (6),
lockwashers (5) and nuts (4). Tighten nuts (4).
b.
Remove tags and connect electrical wires.
3.
NSTALL
LEFT
FRONT
CONTROL
PANEL.
(REFER TO PAGE 8-11.)
4.
CONNECT GROUND CABLE AT SHUNT. (REFER
TO PAGE 8-109.)
5.
START ENGINE. MAKE SURE GAUGE (1)
SHOWS PROPER READINGS. (REFER TO TM 5-
3810-306-10)
END OF TASK
8-18